| Part Number |
EVPE- |
| Power Input |
|
| Input Rating |
230 Vac, Single Phase, 16 A or 32 A Maximum, 50 / 60 Hz |
| Number of Phase / Wire |
L, N and PE (Ground), Hardwired with Terminal Block |
| Standby Power |
< 6.5 W |
| Internal RCD |
30 mA RCD and DC 6 mA RCD Function |
| Power Output |
|
| Output Rating |
230 Vac, Single Phase, 16 A or 32 A Maximum, 50 / 60 Hz; 3.68 kW or 7.4 kW Maximum |
| Charging Interface |
(1) IEC 62196-2 Type 1 or Type 2 Tethered Plug, 5 m Cable(2) IEC 62196-2 Type 2 Socket |
| Protection |
|
| Upstream |
In Accordance with Local Regulations |
| Electrical Protection |
Over Current, Under Voltage, Over Voltage, Residual Current Detection, Surge Protection, Short Circuit, Over Temperature, Ground Fault, Plug-Out Protection |
| Cold-Load Pickup |
Randomized Delay Before Charge Resume After Power Failure |
| Automatic Recovery After Nuisance Trip |
The EVSE Automatically Resumes Charging After Minor Faults Such as OVP, UVP, OTP, or OCP. No User Intervention Required. |
| User Interface & Control |
|
| Status Indicators |
Power, Status, Charge, Fault |
| Buttons & Switch |
Key Switch, On/Off Switch, Reset Button, Emergency Stop Button |
| Charger Configuration |
Charging Current Adjustment |
| Communication |
|
| Network Interface |
Ethernet (Standard), WLAN (Optional), 3G/4G (Optional) |
| Charging Protocol |
OCPP |
| Environment |
|
| Operating Temperature |
-30°C to +50°C (-22°F to +122°F) |
| Storage Temperature |
-40°C to +80°C (-40°F to +176°F) |
| Humidity |
< 95% Relative Humidity, Non-Condensing |
| Altitude |
Up to 2,000 m (6,000 ft.) |
| Mechanical Design |
|
| Ingress Protection |
IP55 |
| Enclosure Protection |
IK08 According to IEC 62262 |
| Cooling |
Natural Cooling |
| Dimensions (W × H × D) / Weight |
318 × 363 × 136 mm (12.6 × 14.3 × 5.4 in), Excluding Charging Cable, Mounting Plate and Cable Holder. Weight: 3.7 kg (8.2 lbs), Without Package |
| Regulation |
|
| Certificate / Compliance |
CE, IEC 61851-1, IEC 61851-2 |
Reviews